Fully compliant with the EN-13231-3 international standard the Rail Corrugation Measuring Systems take precise measurements for the complete wavelength range from the very-short (10-30 mm) to the long bands (300-1000 mm) enabling you to check even the rail grinding works.
The measurement can be done with the train travelling in both directions and with all weather conditions. Each system offers real time data analysis and post processing analysis. Real time functions include data acquisition, storage and diagram visualization in all the wavelengths. Post processing allows for recorded data visualization and standard deviation calculations for each wavelength.
| Served Markets | Versions available | |
| Parameters / Accuracy | Longitudinal Profile in: - Very Short & Short Waves - Medium Waves - Long Waves |
|
| Operating Characteristic | Technology | Optical, No-contact |
| Reproducibility | Very Short, Short, Medium and Long Waves | |
| Measuring Speed | 0 ÷ 200 km/h (0 to 124 mph) | |
| Operating Temperature | -30 to +45 °C (-22 to +113 °F) |
Fully compliant with the EN-13231-3 international standard the Rail Corrugation Measuring Systems take precise measurements for the complete wavelength range from short (30-100 mm) to the long bands (300-1000 mm) enabling you to check even the rail grinding works.
The measurement can be done with the train travelling in both directions and with all weather conditions. Each system offers real time data analysis and post processing analysis. Real time functions include data acquisition, storage and diagram visualization in all the wavelengths. Post processing allows for recorded data visualization and standard deviation calculations foir each wavelength.
| Served Markets | Versions available | |
| Parameters / Accuracy | Longitudinal Profile in: - Short Waves - Medium Waves - Long Waves |
|
| Operating Characteristic | Technology | Optical, No-contact |
| Reproducibility | Short, Short, Medium and Long Waves | |
| Measuring Speed | 0 ÷ 320 km/h (0 to 200 mph) | |
| Operating Temperature | -30 to +45 °C (-22 to +113 °F) |

TecnoLine is a small, easy to manage rail corrugation measuring system. Its measuring principle is based on the measurement of displacements on the rail head trough eddy current transducers, which are very high accuracy sensors.
A PDA interface system makes storing, trasferring and analyzing of data a simple exercise.
| Served Markets | Versions available | |
| Parameters / Accuracy | Longitudinal Profile in: - Very Short - Short Waves - Medium Waves - Long Waves |
|
| Operating Characteristic | Technology | Eddy Current Transducers |
| Measuring Speed | Manually Operated Device |